관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | 13.01 : 의료기, 외과용 도구 및 장비 |
---|---|
적용범위 | 1.1?This specification is intended to provide a characterization of the design and mechanical function of intramedullary fixation devices (IMFDs), specify labeling and material requirements, provide test methods for characterization of IMFD mechanical properties, and identify needs for further development of test methods and performance criteria. The ultimate goal is to develop a standard which defines performance criteria and methods for measurement of performance-related mechanical characteristics of IMFDs and their fixation to bone. It is not the intention of this specification to define levels of performance or case-specific clinical performance of these devices, as insufficient knowledge to predict the consequences of the use of any of these devices in individual patients for specific activities of daily living is available. It is not the intention of this specification to describe or specify specific designs for IMFDs. 1.2?This specification describes IMFDs for surgical fixation of the skeletal system. It provides basic IMFD geometrical definitions, dimensions, classification, and terminology; labeling and material specifications; performance definitions; test methods; and characteristics determined to be important to in vivo performance of the device. 1.3?Multiple test methods are included in this standard. However, the user is not necessarily obligated to test using all of the described methods. Instead, the user should only select, with justification, test methods that are appropriate for a particular device design. This may be only a subset of the herein described test methods. 1.4?This specification includes four standard test methods: 1.4.1?Static Four-Point Bend Test Method?Annex A1. 1.4.2?Static Torsion Test Method?Annex A2. 1.4.3?Bending Fatigue Test Method?Annex A3. 1.4.4?Test Method for Bending Fatigue of IMFD Locking Screws?Annex A4. 1.5?A rationale is given in Appendix X1. 1.6?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
국제분류(ICS)코드 | 11.040.40 : 외과. 보철술. 교정술용 이식 |
페이지수 | 19 |
Edition | 24 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM F1264-24 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2024-08-15 | 표준 |
2 | ASTM F1264-24 REDLINE | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2024-08-15 | 표준 |
3 | ASTM F1264-16e1 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2016-05-01 | 구판 |
4 | ASTM F1264-16 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2016-05-01 | 구판 |
5 | ASTM F1264-14 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2014-11-01 | 구판 |
6 | ASTM F1264-03(2012) | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2012-05-01 | 구판 |
7 | ASTM F1264-03(2007)e2 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2007-10-01 | 구판 |
8 | ASTM F1264-03(2007)e1 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2007-10-01 | 구판 |
9 | ASTM F1264-03(2007) | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2007-10-01 | 구판 |
10 | ASTM F1264-03 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2003-04-10 | 구판 |
11 | ASTM F1264-00 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2001-12-10 | 구판 |
12 | ASTM F1264-01 | Standard Specification and Test Methods for Intramedullary Fixation Devices | 2001-12-10 | 구판 |
관련상품이 존재하지 않습니다.
ISO 17665:2024 - Sterilization of health care products — Moist heat — Requirements for the development, validation and routine control of a sterilization process for medical devices 상세보기
ASTM A276/A276M-24 - Standard Specification for Stainless Steel Bars and Shapes 상세보기
ASTM F1929-23 - Standard Test Method for Detecting Seal Leaks in Porous Medical Packaging by Dye Penetration 상세보기
ASTM F899-23 - Standard Specification for Wrought Stainless Steels for Surgical Instruments 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기