관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | ISO/TC 142 : Cleaning equipment for air and other gases |
---|---|
적용범위 | ISO 16170:2016 specifies in situ test methods for high efficiency particulate air filters used to limit releases towards the environment (e.g. from nuclear facilities or facilities with aerosol toxic or biological releases). This applies where installations of these filters are used to clean effluent air before discharge to the environment from industrial (including nuclear) installations where toxic/radioactive/biological materials are handled or processed. It excludes the application already covered by ISO 14644‑3. The scope of ISO 16170:2016 includes detail of two methods, either of which applies to the periodic testing of high efficiency filters which are used in demanding applications aiming at protecting the environment, such as the nuclear industry. In the case of nuclear applications, ISO 16170:2016 is applicable to installations covered by ISO 17873 (applications other than nuclear reactors) and ISO 26802 (nuclear reactors). The two reference methods specified in ISO 16170:2016 are not equivalent, but related to, the requirements to be addressed by the test results. The choice of which of the two methods is adopted in any specific case depends on whether the outcome requires an integrity test or a statutory efficiency accountancy test. For industries handling or processing radioactive or toxic materials giving rise to a risk of possible release, the main goal of the tests is to confirm that the filter installation is fit for purpose. In the case of integrity tests (Annex B), this is to confirm that no significant leakage of toxic aerosols through the filter installation is possible. In the case of efficiency accountancy tests (Annex C), the test is designed to make an accurate measurement of decontamination factor with respect to the MPPS size range of particles. The reference method described in Annex B (integrity test) requires a test aerosol of dispersed oil particles mainly submicrometre in size range, which is stable during the test procedure and compatible with other installation components. Particle concentrations are measured in real time by light scattering instrumentation (optical detectors). The reference method described in Annex C (efficiency accountancy test) requires a test aerosol of particles having a narrow size range centred on MPPS size range for HEPA filter media. Their concentration both upstream and downstream the filters is measured by fluorimetric analysis of aqueous solution obtained by washing the membrane sampling filters. It should be noted that the requirements for an efficiency accountancy test also cover the requirements of an integrity test, which is considered to be a minimum requirement. Test methods developed in ISO 16170:2016 do not cover the other in situ performance requirements, such as mechanical resistance, bursting resistance or humidity resistance. Specific systems operating at high temperature or with specific gaseous effluents might require specific test methods. The engineering design of HEPA and ULPA filter installations does not fall within the scope of ISO 16170:2016. NOTE In the field of filters for general ventilation applications, ISO 29462 is a detailed and comprehensive description of a method which uses scanning and particle counting methods to evaluate the performance of a filter in terms of particle grade efficiency, as well as pressure drop. Such a method and procedure would not be applicable in those nuclear installations where quantification of the decontamination factor at MPPS size is needed. |
국제분류(ICS)코드 | 91.140.30 : 통풍 및 공기 조절체계 |
페이지수 | 36 |
Edition | 1 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ISO 16170:2016 | In situ test methods for high efficiency filter systems in industrial facilities | 2016-06-27 | 표준 |
관련상품이 존재하지 않습니다.
ISO 15957:2015 - Test dusts for evaluating air cleaning equipment 상세보기
ISO 10313:1993 - Ambient air — Determination of the mass concentration of ozone — Chemiluminescence method 상세보기
ISO 29462:2013 - Field testing of general ventilation filtration devices and systems for in situ removal efficiency by particle size and resistance to airflow 상세보기
EPA METHOD 680 :1985 - DETERMINATION OF PESTICIDES AND PCBS IN WATER AND SOIL/SEDIMENT BY GAS CHROMATOGRAPHY/MASS SPECTROMETRY 상세보기
ISO 20468-3:2020 - Guidelines for performance evaluation of treatment technologies for water reuse systems — Part 3: Ozone treatment technology 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기