관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | TC 62/SC 62D : Particular medical equipment, software, and systems |
---|---|
적용범위 | IEC 60601-2-41:2021 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL LUMINAIRES and LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. This particular standard does not apply to – headlights; – endoscopes, laparoscopes and their light sources, which are covered by IEC 60601-2-18; – luminaires used in dentistry, which are covered by ISO 9680; – luminaires for general purposes, which are covered by IEC 60598-2-1 and IEC 60598-2-4; – luminaires dedicated to therapeutic purposes; – special purpose lights with different conditions of use such as light sources intended solely for decontamination of air and surfaces, UV lights for dermatological diagnosis, slit lamps for ophthalmology, lights for surgical microscopes and lights for surgical navigation systems; – lights connected to surgical instruments, such as luminous retractors; – luminaires for emergency lighting, which are covered by IEC 60598-2-22. SURGICAL LUMINAIRES and LUMINAIRES FOR DIAGNOSIS are medical devices and not general lighting equipment. IEC 60601-2-41:2021 cancels and replaces the second edition published in 2009 and Amendment 1:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) revised the statement of essential performance; b) added exposure limits, test conditions, calculation methods and safety warnings related to photobiological hazards; c) removed the terms “MINOR SURGICAL LUMINAIRES” and “MAJOR SURGICAL LUMINAIRES”; d) added definitions of MAXIMUM ILLUMINANCE DISTANCE and REFERENCE DISTANCE and allowed MANUFACTURERS to measure some performance characteristics at the REFERENCE DISTANCE that they specify; e) replaced the region of acceptable chromaticity in (x,y) colour space with a requirement for Du,v; f) added a requirement for acceptable drift of the lighthead when attached to the suspension system; g) added a requirement for fluid ingress protection; h) revised Table 201.101 of IEC 60601-2-41:2009 and IEC 60601-2-41:2009/AMD1:2013 and moved it to Annex BB; i) specified a new device for measuring SHADOW DILUTION in a simulated cavity; j) specified test conditions for luminaires equipped with distance sensors. |
국제분류(ICS)코드 |
11.040.99 : 기타 의료장비
11.040.20 : 수혈. 주입. 주사장비 11.040.55 : 진단장비 |
페이지수 | 120 |
Edition | 3.0 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60601-2-41:2021 | Medical electrical equipment - Part 2-41: Particular requirements for the basic safety and essential performance of surgical luminaires and luminaires for diagnosis | 2021-09-03 | 표준 |
2 | IEC 60601-2-41:2009/AMD1:2013 | Amendment 1 - Medical electrical equipment - Part 2-41: Particular requirements for the basic safety and essential performance of surgical luminaires and luminaires for diagnosis | 2013-10-29 | 구판 |
3 | IEC 60601-2-41:2009+AMD1:2013 CSV | Medical electrical equipment - Part 2-41: Particular requirementsfor the basic safety and essential performance of surgical luminaires and luminaires for diagnosis | 2013-10-29 | 구판 |
4 | IEC 60601-2-41:2009 | Medical electrical equipment - Part 2-41: Particular requirements for the basic safety and essential performance of surgical luminaires and luminaires for diagnosis | 2009-08-12 | 구판 |
5 | IEC 60601-2-41:2000 | Medical electrical equipment - Part 2-41: Particular requirements for the safety of surgical luminaires and luminaires for diagnosis | 2000-02-24 | 구판 |
IEC/DIS 60601-2-26 - Medical electrical equipment — Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs 상세보기
IEC 60601-2-15:1988 - Medical electrical equipment. Part 2: Particular requirements for the safety of capacitor discharge X-ray generators 상세보기
IEC 60601-2-14:1989 - Medical electrical equipment. Part 2: Particular requirements for the safety of electroconvulsive therapy equipment 상세보기
IEC 60601-2-32:1994 - Medical electrical equipment - Part 2: Particular requirements for the safety of associated equipment of X-ray equipment 상세보기
IEC 60601-1-4:1996 - Medical electrical equipment - Part 1: General requirements for safety - 4. Collateral standard: Programmable electrical medical systems 상세보기
ASTM F2743-11(2018) - Standard Guide for Coating Inspection and Acute Particulate Characterization of Coated Drug-Eluting Vascular Stent Systems 상세보기
ASTM F1984-99(2018) - Standard Practice for Testing for Whole Complement Activation in Serum by Solid Materials 상세보기
ASTM F2394-07(2017) - Standard Guide for Measuring Securement of Balloon Expandable Vascular Stent Mounted on Delivery System 상세보기
ASTM F2514-08(2014) - Standard Guide for Finite Element Analysis (FEA) of Metallic Vascular Stents Subjected to Uniform Radial Loading 상세보기
AAMI TIR42 : 2021 Edition, 2021 - Evaluation of particulate associated with vascular medical devices 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기