관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | |
---|---|
적용범위 | Preface This is the first edition of the CSA SPE-900, Solar photovoltaic rooftop-installation best practices guideline. CSA SPE-900 has been developed as a guideline, and does not contain any mandatory language. It provides guidance and best practices for solar photovoltaic rooftop-installation.? CSA Group acknowledges that the development of this Guideline was made possible, in part, by the financial support of the following: (a) Axis Property (b) BCHydro (c) Hydro Quebec (d) Manitoba Hydro (e) Ontario Ministry of Energy (f) SaskPower Scope 1.1 There is a need in the Canadian marketplace for guidance on solar photovoltaic rooftop installation, as photovoltaic modules are not currently addressed in many of the building codes. This guideline is intended to outline best practices for rooftop solar photovoltaic systems by addressing the following:? (a) structural analysis of the building itself resulting from the solar photovoltaic system installation? (b) structural analysis of the solar photovoltaic racking (c) flammability of rooftop solar photovoltaic mounting systems (d) preventing water penetration of the roofing system due to the installation of a solar photovoltaic system? (e) climbing hazards associated with solar photovoltaic system installations (f) avalanche hazards (due to snow and wind loads) associated with solar photovoltaic installation (g) safe roof access for first responders (i.e., fire fighters) in the event of an emergency or maintenance personnel (e.g., electricians, window cleaners, or other service personnel)? 1.2 This guideline is intended to be used by solar photovoltaic system designers, installers, system owners, local building officials, fire departments, insurers, project financiers, etc.? 1.3 The values given in SI (metric) units are the standard. Any values given in parentheses are for information only.? 1.4 This guideline addresses rooftop solar photovoltaic systems only. It is applicable to residential, institutional, commercial, and industrial (ICI) buildings with either flat roofs or pitched roofs. While the focus is on rooftop-mounted systems, some of the principles described herein can be applied to photovoltaic systems mounted to facades, carports, awnings, sound barriers, and other building structures. This guideline will also examine different roofing materials and systems, including membranes, standing-seam metal roofing, steel high-rib roofing, steel shingle, asphalt, tile, slate, cedar shakes, and green roofs. Lastly, it will take into consideration the structure itself, including the structural systems and type of building materials (e.g., wood-frame rafters and joists, prefabricated wood trusses, structural steel beams and joists, and other systems in steel, masonry, concrete, and wood).? 1.5 It is important to note that this guideline does not address solar photovoltaic system electrical hazards, as these issues are addressed by the Canadian Electrical Code, Part I (CEC). However, this guideline does direct the user to the appropriate sections of the CEC as required. In addition, this guideline does not address building-integrated solar photovoltaic systems (BIPV).? 1.6 Reference to the National Building Code of Canada (NBCC) implies the adopted versions of the National Building Code of Canada by provincial and regional authorities throughout Canada.? 1.7 It is advisable to contact local municipalities (or building authority) to determine electrical and structural permit requirements for the installation of photovoltaic rooftop installations for the photovoltaic system and the building itself. Requirements for zoning, new developments, and photovoltaic design may vary.? 1.8 In this guideline, "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the guideline; and "can" is used to express possibility or capability. |
국제분류(ICS)코드 | |
페이지수 | 78 |
Edition |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | SPE-900-13 | Solar photovoltaic rooftop-installation best practices guideline | 2013-01-01 | 표준 |
SPE-7002-14 - Sustainability standard for household portable and floor care appliances (Bi-national standard, with AHAM 7002-2014 and UL 7002) 상세보기
SPE-14040-14 - Life cycle assessment of auto parts - Guidelines for conducting LCA of auto parts incorporating weight changes due to material composition, manufacturing technology, or part geometry 상세보기
SPE-890-15 - A Guideline for accountable management of end-of-life materials 상세보기
SPE-2.1 SERIES-18 - Best practices for defueling, decommissioning, and disposal of compressed natural gas vehicle fuel containers and liquefied natural gas vehicle fuel tanks 상세보기
CSA SPE-3000:19 - Model code for the field evaluation of medical electrical equipment (MEE) and medical electrical systems (MES) 상세보기
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기