관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | |
---|---|
적용범위 | IEC 60079-2:2014 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition. IEC 60079-2:2014 contains the specific requirements for the construction and testing of electrical equipment with pressurized enclosures, of type of protection "p", intended for use in explosive gas atmospheres or explosive dust atmospheres. It also includes the requirements for pressurized enclosures containing a limited release of a flammable substance. This standard supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirements of this standard take precedence. This standard does not include the requirements for: - pressurized enclosures where the containment system may release air with an oxygen content greater than normal, or oxygen in combination with inert gas where the oxygen is in a proportion greater than 21 %; - pressurized rooms or analyser houses; see IEC 60079-13; - pressurized enclosures used where "explosives" or pyrotechnics are present; - pressurized enclosures used where hybrid mixtures of gas/vapour and combustible dust are present; - pressurized enclosures used where pyrophoric substances such as explosives or propellants containing their own oxidizers are present; - pressurized enclosures with an internal source of release of combustible dust. This sixth edition cancels and replaces the fifth edition published in 2007. This sixth edition cancels and replaces the first edition of IEC 61241-4 published in 2001. This sixth edition constitutes a technical revision. The significance of changes between IEC 60079-2, Edition 6.0, 2014 and IEC 60079-2, Edition 5.0, 2007 are as listed in the foreword of the document. Keywords: electrical equipment with pressurized enclosures, type of protection "p", explosive gas atmospheres, explosive dust atmospheres The contents of the corrigendum of July 2015 have been included in this copy. |
국제분류(ICS)코드 | 29.260.20 : 폭발 환경용 전기장치 |
페이지수 | 214 |
Edition | 6.0 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60079-2:2014/COR1:2015 | Corrigendum 1 - Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p" | 2015-07-07 | 표준 |
2 | IEC 60079-2:2014 RLV | Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p" | 2014-07-21 | 표준 |
3 | IEC 60079-2:2014 | Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p" | 2014-07-21 | 표준 |
4 | IEC 60079-2:2007 | Explosive atmospheres - Part 2: Equipment protection by pressurized enclosures "p" | 2007-02-22 | 구판 |
5 | IEC 60079-2:2001 | Electrical apparatus for explosive gas atmospheres - Part 2: Pressurized enclosures "p" | 2001-02-27 | 구판 |
6 | IEC 60079-2:1983 | Electrical apparatus for explosive gas atmospheres. Part 2: Electrical apparatus, type of protection 'p' | 1983-01-01 | 구판 |
7 | IEC 60079-2:1975 | Electrical apparatus for explosive gas atmospheres - Part 2: Pressurized enclosures | 1975-01-01 | 구판 |
8 | IEC 60079-2:1962 | Electrical apparatus for explosive gas atmospheres - Part 2: Pressurized enclosures | 1962-01-01 | 구판 |
IEC 60079-8:1969 - Electrical apparatus for explosive gas atmospheres - Part 8: Classification of maximum surface temperatures 상세보기
IEC 60079-4A:1970 - Electrical apparatus for explosive gas atmospheres - Part 4: Method of test for ignition temperature - First supplement. *Note.-This supplement applies also to the second edition of 1975 상세보기
IEC 60079-9:1970 - Electrical apparatus for explosive gas atmospheres - Part 9: Marking 상세보기
IEC 60079-8:1969/AMD1:1972 - Amendment 1 - Electrical apparatus for explosive gas atmospheres - Part 8: Classification of maximum surface temperatures 상세보기
IEC 60079-4:1975 - Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature 상세보기
IEC 60079-0:2017 RLV - Explosive atmospheres - Part 0: Equipment - General requirements 상세보기
IEC 60079-17:2013 - Explosive atmospheres - Part 17: Electrical installations inspection and maintenance 상세보기
IEC 60079-14:2013 - Explosive atmospheres - Part 14: Electrical installations design, selection and erection 상세보기
IEC 60079-7:2015+AMD1:2017 CSV - Explosive atmospheres - Part 7: Equipment protection by increased safety "e" 상세보기
IEC 60079-18:2014+AMD1:2017 CSV - Explosive atmospheres - Part 18: Equipment protection by encapsulation "m" 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기