분야 | TC 62/SC 62B : Medical imaging equipment, software, and systems |
---|---|
적용범위 | IEC 60601-2-54:2022 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ME EQUIPMENT and ME SYSTEMS intended to be used for projection RADIOGRAPHY and INDIRECT RADIOSCOPY. IEC 60601-2-43 applies to ME EQUIPMENT and ME SYSTEMS intended to be used for interventional applications and refers to applicable requirements in this document. ME EQUIPMENT and ME SYSTEMS intended to be used for bone or tissue absorption densitometry, computed tomography, mammography or dental or radiotherapy applications are excluded from the scope of this document. The scope of this document also excludes radiotherapy simulators. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. IEC 60601-2-54:2022 edition cancels and replaces the first edition published in 2009, Amendment 1:2015 and Amendment 2:2018. This edition constitutes a technical revision. This edition includes editorial and technical changes to reflect the IEC 60601 1:2005/AMD2:2020. It also contains corrections and technical improvements. Significant technical changes with respect to the previous edition are as follows: a) a new specific term DOSIMETER is introduced to replace the general term DOSEMETER; b) terms and definitions taken exclusively from IEC TR 60788:2004 and which are specifically applicable in this document have been moved to 201.3; c) the collateral standards IEC 60601-1-11:2015, IEC 60601-1-11:2015/AMD1:2020, IEC 60601-1-12:2014 and IEC 60601-1-12:2014/AMD1:2020 are applicable if MANUFACTURER so declares; d) the subclause 201.11.101 “Protection against excessive temperatures of X-ray tube assemblies” has been removed from this document as its requirements are sufficiently and clearly covered by IEC 60601-1:2005, IEC 60601-1:2005/AMD1:2012, IEC 60601-1:2005/AMD2:2020 and IEC 60601-2-28:2017; e) to adopt changes which are introduced with respect to indicator lights in 7.8.1 of the IEC 60601-1:2005/AMD2:2020 clarification of requirements is provided to avoid conflicts with requirements of indicator lights stipulated for X-RAY EQUIPMENT; f) explanation of the term ESSENTIAL PERFORMANCE is provided in Annex AA to emphasize the performance of the clinical function under NORMAL and SINGLE FAULT CONDITIONS. CONDITIONS. |
국제분류(ICS)코드 | 11.040.50 : 방사선 및 기타 진단 기기 |
페이지수 | 161 |
Edition | 2.0 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60601-2-54:2022 | Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy | 2022-09-26 | 표준 |
2 | IEC 60601-2-54:2022 RLV | Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy | 2022-09-26 | 표준 |
3 | IEC 60601-2-54:2009+AMD1:2015+AMD2:2018 CSV | Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy | 2018-06-29 | 구판 |
4 | IEC 60601-2-54:2009/AMD2:2018 | Amendment 2 - Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy | 2018-06-29 | 구판 |
5 | IEC 60601-2-54:2009/AMD1:2015 | Amendment 1 - Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy | 2015-04-17 | 구판 |
6 | IEC 60601-2-54:2009+AMD1:2015 CSV | Medical electrical equipment - Part 2-54: Particular requirementsfor the basic safety and essential performance of X-ray equipmentfor radiography and radioscopy | 2015-04-17 | 구판 |
7 | IEC 60601-2-54:2009/COR2:2011 | Corrigendum 2 - Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy | 2011-06-10 | 구판 |
8 | IEC 60601-2-54:2009/COR1:2010 | Corrigendum 1 - Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy | 2010-03-10 | 구판 |
9 | IEC 60601-2-54:2009 | Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy | 2009-06-29 | 구판 |
IEC/DIS 60601-2-26 - Medical electrical equipment — Part 2-26: Particular requirements for the basic safety and essential performance of electroencephalographs 상세보기
IEC 60601-2-15:1988 - Medical electrical equipment. Part 2: Particular requirements for the safety of capacitor discharge X-ray generators 상세보기
IEC 60601-2-14:1989 - Medical electrical equipment. Part 2: Particular requirements for the safety of electroconvulsive therapy equipment 상세보기
IEC 60601-2-32:1994 - Medical electrical equipment - Part 2: Particular requirements for the safety of associated equipment of X-ray equipment 상세보기
IEC 60601-1-4:1996 - Medical electrical equipment - Part 1: General requirements for safety - 4. Collateral standard: Programmable electrical medical systems 상세보기
IEC 60601-1-6:2010/AMD2:2020 - Amendment 2 - Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability 상세보기
IEC 60601-1-8:2006/AMD2:2020 - Amendment 2 - Medical electrical equipment - Part 1-8: General requirements for basic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems 상세보기
IEC 60601-2-45:2011/AMD2:2022 - Amendment 2 - Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices 상세보기
ASTM D4332-22 REDLINE - Standard Practice for Conditioning Containers, Packages, or Packaging Components for Testing 상세보기
ASTM D4169-22 REDLINE - Standard Practice for Performance Testing of Shipping Containers and Systems 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기