관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | CISPR/CIS/A : Radio-interference measurements and statistical methods |
---|---|
적용범위 | CISPR 16-1-3:2004+A1:2016 is designated a basic standard, which specifies the characteristics and calibration of the absorbing clamp for the measurement of radio disturbance power in the frequency range 30 MHz to 1 GHz. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. In this edition a more detailed calibration method for the absorbing clamp is specified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one which was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the of the absorbing clamp test site (ACTS) is also included in the document. The contents of the corrigendum of February 2006 have been included in this copy. This consolidated version consists of the second edition (2004) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication. |
국제분류(ICS)코드 |
33.100.20 : 내성
33.100.10 : 방사 |
페이지수 | 136 |
Edition | 2.1 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | CISPR 16-1-3:2004/AMD2:2020 | Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power | 2020-01-28 | 표준 |
2 | CISPR 16-1-3:2004+AMD1:2016+AMD2:2020 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power | 2020-01-28 | 표준 |
3 | CISPR 16-1-3:2004+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power | 2016-03-31 | 표준 |
4 | CISPR 16-1-3:2004/AMD1:2016 | Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power | 2016-03-31 | 표준 |
5 | CISPR 16-1-3:2004/COR1:2006 | Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power | 2006-02-09 | 표준 |
6 | CISPR 16-1-3:2004 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power | 2004-06-28 | 표준 |
7 | CISPR 16-1-3:2003 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power | 2003-11-19 | 구판 |
CISPR 16-1:1999 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus 상세보기
CISPR TR 16-3:2000 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: Reports and recommendations of CISPR 상세보기
CISPR 16-4:2002 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 4: Uncertainty in EMC measurements 상세보기
CISPR TR 16-3:2000/AMD1:2002 - Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: Reports and recommendations of CISPR 상세보기
CISPR 16-1:1999/AMD1:2002 - Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus 상세보기
CISPR 16-1-5:2014+AMD1:2016 CSV - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz 상세보기
CISPR 16-2-1:2014+AMD1:2017 CSV - Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements 상세보기
AS CISPR 16.3:2013 - Specification for radio disturbance and immunity measuring apparatus and methods CISPR technical reports 상세보기
AS/NZS CISPR 16.3:2013/Amdt 1:2017 - Specification for radio disturbance and immunity measuring apparatus and methods CISPR technical reports 상세보기
AS/NZS CISPR 32:2015 - Electromagnetic compatibility of multimedia equipment - Emission requirements 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기