분야 | CISPR/CIS/H : Limits for the protection of radio services |
---|---|
적용범위 | IEC 61000-6-4:2006+A1:2010 This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in industrial environments as described below. Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified. This generic EMC emission standard is applicable if no relevant dedicated product or product-family EMC emission standard exists. This standard applies to a apparatus intended to be connected to a power network supplied from a high or medium voltage transformer dedicated to the supply of an installation feeding manufacturing or similar plant, and intended to operate in or in proximity to industrial locations, as described below. This standard applies also to apparatus, which is battery operated and intended to be used in industrial locations. The environments encompassed by this standard are industrial, both indoor and outdoor. Industrial locations are in addition characterised by the existence of one or more of the following examples: - industrial, scientific and medical (ISM) apparatus; - heavy inductive or capacitive loads that are frequently switched; - high currents and associated magnetic fields. The object of this standard is to define the emission test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances. The emission requirements have been selected so as to ensure that disturbances generated by apparatus operating normally in industrial locations do not exceed a level that could prevent other apparatus from operating as intended. Fault conditions of apparatus are not taken into account. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These requirements represent essential electromagnetic compatibility emission requirements. Requirements are specified for each port considered. This consolidated version consists of the second edition (2006) and its amendment 1 (2010). Therefore, no need to order amendment in addition to this publication. |
국제분류(ICS)코드 | 33.100.10 : 방사 |
페이지수 | 37 |
Edition | 2.1 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 61000-6-4:2018 RLV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments | 2018-02-07 | 표준 |
2 | IEC 61000-6-4:2018 | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments | 2018-02-07 | 표준 |
3 | IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments | 2011-02-23 | 구판 |
4 | IEC 61000-6-4:2006/AMD1:2010 | Amendment 1 - Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments | 2010-12-08 | 구판 |
5 | IEC 61000-6-4:2006 | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments | 2006-07-10 | 구판 |
6 | IEC 61000-6-4:1997 | Electromagnetic compatibility (EMC) - Part 6: Generic standards - Section 4: Emission standard for industrial environments | 1997-01-30 | 구판 |
IEC TR 61000-2-1:1990 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems 상세보기
IEC TR 61000-2-3:1992 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 3: Description of the environment - Radiated and non-network-frequency-related conducted phenomena 상세보기
IEC 61000-4-12:1995 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 12: Oscillatory waves immunity test. Basic EMC Publication 상세보기
IEC TR 61000-2-6:1995 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 6: Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances 상세보기
IEC 61000-5-5:1996 - Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance. Basic EMC Publication 상세보기
IEC 61000-4-8:2009 - Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기