분야 | TC 77/SC 77B : High frequency phenomena |
---|---|
적용범위 | IEC 61000-4-21:2011 considers tests of immunity and intentional or unintentional emissions for electric and/or electronic equipment and tests of screening effectiveness in reverberation chambers. It establishes the required test procedures for performing such tests. Only radiated phenomena are considered. The objective of IEC 61000-4-21:2011 is to establish a common reference for using reverberation chambers to evaluate the performance of electric and electronic equipment when subjected to radio-frequency electromagnetic fields and for determining the levels of radio-frequency radiation emitted from electric and electronic equipment. IEC 61000-4-21:2011 does not intend to specify the tests to be applied to a particular apparatus or system. Its main aim is to give a general basic reference to all concerned product committees of the IEC. The product committees should select emission limits and test methods in consultation with CISPR. The product committees remain responsible for the appropriate choice of the immunity tests and the immunity test limits to be applied to their equipment. Other methods, such as those covered in IEC 61000-4-3, CISPR 16-2-3 and CISPR 16-2-4 may be used. This second edition cancels and replaces the first edition published in 2003. This edition constitutes a technical revision and includes the following significant technical changes with respectto the first edition: - In Clause 8, the use and specifications of E-field probes for application to reverberation chambers has been added. - In Annex A, additional guidance and clarifications on the use of reverberation chambers at relatively low frequencies of operation (i.e., close to the lowest usable frequency of a given chamber) are given, and its implications on the estimation of field uncertainty are outlined. - In Annex B, symmetric location of the field probes when the chamber exhibits cylindrical symmetry has been disallowed, as such placement could otherwise yield a false indication of field uniformity and chamber performance at different locations. - Annex C now contains more quantitative guidance on the setting of the maximum permissible stirring speeds that warrant quasi-static conditions of operation for chamber validation and testing. - In Annex D, a requirement for the EUT and equipment not to occupy more than 8 % of the total chamber volume in immunity testing has been added. - Annex E has been extended with further guidance on the value of EUT directivity to be used in the estimation of radiated power and field. - In Annex I, some clarifications on antenna efficiency measurements have been added. - A new Annex K has been added that covers measurement uncertainty in reverberation chambers. |
국제분류(ICS)코드 |
33.100.20 : 내성
33.100.10 : 방사 |
페이지수 | 224 |
Edition | 2.0 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 61000-4-21:2011 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods | 2011-01-27 | 표준 |
2 | IEC 61000-4-21:2003 | Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods | 2003-08-26 | 구판 |
IEC TR 61000-2-1:1990 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems 상세보기
IEC TR 61000-2-3:1992 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 3: Description of the environment - Radiated and non-network-frequency-related conducted phenomena 상세보기
IEC 61000-4-12:1995 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 12: Oscillatory waves immunity test. Basic EMC Publication 상세보기
IEC TR 61000-2-6:1995 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 6: Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances 상세보기
IEC 61000-5-5:1996 - Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance. Basic EMC Publication 상세보기
IEC 61000-4-4:2012 - Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test 상세보기
IEC 61000-4-19:2014 - Electromagnetic compatibility (EMC) - Part 4-19: Testing and measurement techniques - Test for immunity to conducted, differential mode disturbances and signalling in the frequency range 2 kHz to 150 kHz at a.c. power ports 상세보기
IEC 61000-4-2:2008 - Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test 상세보기
IEC TR 61000-4-35:2009 - Electromagnetic compatibility (EMC) - Part 4-35: Testing and measurement techniques - HPEM simulator compendium 상세보기
IEC 61000-4-8:2009 - Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기