관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
Electromagnetic compatibility (EMC) - Part 2: Environment - Section 7: Low frequency magnetic fields in various environments (Adopted CEI/IEC 61000-2-7:1998, first edition, 1998-01, with Canadian deviations) | Compatibilité électromagnétique (CEM) - Parti
분야 | 11 : LG Electronics |
---|---|
적용범위 | Scope Interest in magnetic fields has been stimulated in recent years by concern over the physiological effects they may have on humans and animals and the deleterious effects they have on the performance of some electrical equipment, particularly video display units. Investigations have yielded results which are presented in this report as reference values.? Note 1 - The European Union EMC Directive has prompted magnetic field measurements, particularly in respect of the commercial office environments associated with supply authority substations and electrical distribution systems within buildings. Supply authorities have sponsored most of the work and the results are generally within the frequency range of 50 Hz to 2 kHz, and presented as r.m.s. values. There is, however, a need to have some knowledge about d.c. fields and the fields up to 150 kHz as they may interfere with some types of equipment.? Note 2 - Most of the magnetic field data in this report is associated with sinusoidal current sources and r.m.s. values may be assumed unless otherwise stated. Power supply systems operating at voltages less than or equal to 1 000 V are designated low-voltage, those above 1 000 V and up to 35 kV are designated medium-voltage, and those in excess of 35 kV are designated high-voltage.? --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------? Domaine d’application Les champs magn?tiques ont ?t? l'objet d'un regain d'int?r?t au cours de ces derni?res ann?es en raison des effets physiologiques qu'ils peuvent avoir sur les ?tres humains et les animaux et des effets d?favorables qu'ils ont sur le fonctionnement de certains ?quipements ?lectriques, notamment les ?crans de visualisation. Les r?sultats des recherches sont pr?sent?s dans ce rapport comme valeurs de r?f?rence.? NOTE 1 - La Directive CEM de la Commission Europ?enne a suscit? de faire des mesures de champs magn?tiques, particuli?rement dans des environnements de bureaux commerciaux ? proximit? de postes appartenant ? des compagnies d'?lectricit? ainsi que dans des environnements de r?seaux de distribution d'?lectricit? ? l'int?rieur des b?timents. Les distributeurs d'?lectricit? ont support? financi?rement la plupart des travaux et les r?sultats se situent g?n?ralement dans la gamme de fr?quence allant de 50 Hz ? 2 kHz et sont pr?sent?s comme des valeurs efficaces. Il est toutefois n?cessaire de conna?tre quelque peu les champs magn?tiques jusqu'? 150 kHz car ils interf?rent avec certains types d'appareils.? NOTE 2 - La plupart des valeurs de champs magn?tiques indiqu?es dans ce rapport correspondent ? des sources de courant sinuso?dal et on peut les consid?rer comme des valeurs efficaces sauf indications contraires. Les r?seaux d'alimentation de tensions inf?rieures ou ?gales ? 1 000 V sont consid?r?s comme des r?seaux basse tension, ceux exploit?s ? des tensions sup?rieures ? 1 000 V allant jusqu'? 35 kV comme des r?seaux moyenne tension et enfin ceux exploit?s ? des tensions sup?rieures ? 35 kV comme des r?seaux haute tension. |
국제분류(ICS)코드 | |
페이지수 | 99 |
Edition |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | CAN/CSA-C61000-2-7:04 (R2022) | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 7: Low frequency magnetic fields in various environments (Adopted CEI/IEC 61000-2-7:1998, first edition, 1998-01, with Canadian deviations) | Compatibilité électromagnétique (CEM) - Parti | 2004-01-01 | 표준 |
CAN/CSA-C61000-2-2:04 (R2023) - Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems (Adopted CEI/IEC 61000-2-2:2002, second edition, 2002-03, with Canadian d 상세보기
CAN/CSA-C61000-2-12:04 (R2023) - Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems (Adopted CEI/IEC 61000-2-12:2003, first edition, 2003-04, with Canadi 상세보기
CAN/CSA-C61000-3-13-09 (R2022) - Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the connection of unbalanced installations to MV, HV and EHV power systems (Adopted IEC/TR 61000-3-13:2008, first edition, 2008-02) 상세보기
CAN/CSA-C61000-3-7:09 (R2022) - Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems (Adopted IEC/TR 61000-3-7:2008, second edition, 2008-02) 상세보기
CAN/CSA-C61000-3-6:09 (R2023) - Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems (Adopted IEC/TR 61000-3-6:2008, second edition, 2008-02, with Canadian deviations) 상세보기
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기