관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | |
---|---|
적용범위 | 1.1?This guide describes methods for characterizing the efficacy, under prescribed laboratory conditions, of a brush part designed to clean the external surface of a medical device. The method utilizes force testers to mechanically actuate a brush part across a surface at a constant rate and constant pressure. In the first method, the force required to actuate across the surface is measured. In the next method, which utilizes the same force testers and protocol (actuation motion), the brush part is actuated on a soiled surface and the amount of soil removed is measured, as another indicator of performance. 1.2?Brushes designed to clean medical devices after clinical use play an important role in the effective reprocessing of those medical devices. 1.3?Inclusions:? 1.3.1?This guide describes objective, quantifiable, and reproducible methods for evaluating the cleaning characteristics of a brush part, under prescribed laboratory conditions, with a test method that simulates the cleaning challenge of a defined target area(s) of a medical device. This also makes it possible to compare one brush part design to another. 1.3.2?By use of this guide, manufacturers of cleaning brushes will be able to evaluate and characterize the cleaning performance of their brushes for the target area(s) of medical device(s) and evaluate modifications to design and construction that might improve performance. 1.3.3?By use of this guide, this information can also be shared with the users of the brushes (medical device reprocessors) to help them evaluate the performance of commercially available brushes. 1.4?Exclusions:? 1.4.1?This guide is not intended to be used for brushes designed to clean medical devices using rotational motion. 1.4.2?This guide does not assess potential damage that may be inflicted by the brush, or degradation of the brush that may occur during repeated use. Brushes with rigid bristles (for example, stainless steel or other metals) are predicted to be more likely to damage medical devices than brushes with flexible bristles (for example, nylon); damage from rigid-bristled brushes should be assessed. Assessing repeated use would require a greatly increased number of test repetitions than what is described in this guide. 1.4.3?This guide does not specify acceptance criteria, and the results will be dependent on the specific parameters that are tested (for example, test soil, drying time, surface area, and materials, etc.) that are tested. 1.4.4?This guide is not intended to constitute all steps required to conduct validation of cleaning instructions for a medical device, including use of brushes for this purpose, but provides methods that may be part of a broader protocol to conduct a complete cleaning instructions validation. Separate medical device cleaning instruction validation studies must be conducted. 1.5?Units?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
국제분류(ICS)코드 | |
페이지수 | 11 |
Edition | 22 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM F3276-22 | Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device | 2022-01-01 | 표준 |
2 | ASTM F3276-22 REDLINE | Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device | 2022-01-01 | 표준 |
3 | ASTM F3276-19 | Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device | 2019-02-15 | 구판 |
관련상품이 존재하지 않습니다.
BS EN 55011:2016+A2:2021 ExComm - SET - Industrial, scientific and medical equipment. Radio-frequency disturbance characteristics. Limits and methods of measurement. 상세보기
BS EN IEC 61000-6-3:2021 ExComm - SET - Electromagnetic compatibility (EMC). Generic standards. Emission standard for equipment in residential environments. 상세보기
BS EN 55032:2015+A1:2020 ExComm - SET - Electromagnetic compatibility of multimedia equipment. Emission requirements. 상세보기
BS ISO/IEC 27701:2019 ExComm - Security techniques. Extension to ISO/IEC 27001 and ISO/IEC 27002 for privacy information management. Requirements and guidelines. 상세보기
ASTM F3275-22 REDLINE - Standard Guide for Using a Force Tester to Evaluate Performance of a Brush Part Designed to Clean the Internal Channel of a Medical Device 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기