관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | 08.04 : 플라스틱 파이프 및 건축용 제품 |
---|---|
적용범위 | 1.1?This test method covers a standardized method to determine the performance of excess flow valves (EFVs) designed to limit flow or stop flow in thermoplastic natural gas service lines.2 1.2?All tests are intended to be performed using air as the test fluid. Unless otherwise stated, all flow rates are reported in standard cubic feet per hour of 0.6 relative density natural gas. 1.3?The test method recognizes two types of EFV. One type, an excess flow valve-bypass (EFVB), allows a small amount of gas to bleed through (bypass) after it has tripped, usually as a means of automatically resetting the device. The second type, an excess flow valve-non bypass (EFVNB), is intended to trip shut forming an essentially gas tight seal. 1.4?The performance characteristics covered in this test method include flow at trip point, pressure drop across the EFV, bypass flow rate of the EFVB or leak rate through the EFVNB after trip, and verification that the EFV can be reset. 1.4.1?Gas distribution systems may contain condensates and particulates such as organic matter, sand, dirt, and iron compounds. Field experience has shown that the operating characteristics of some EFVs may be affected by accumulations of these materials. The tests of Section 11 were developed to provide a simple, inexpensive, reproducible test that quantifies the effect, if any, of a uniform coating of kerosene and of kerosene contaminated with a specified amount of ferric oxide powder on an EFV's operating characteristics. 1.5?Excess flow valves covered by this test method will normally have the following characteristics: a pressure rating of up to 125 psig (0.86 MPa); a trip flow of between 200?ft3/h and 2500 ft3/h (5.66?m3/h and 70.8 m3/h) at 10 psig (0.07 MPa); a minimum temperature rating of 0°F(?18°C), and a maximum temperature rating of 100?°F (38?°C). 1.6?The EFVs covered by this test method shall be constructed to fit piping systems no smaller than 1/2?CTS and no larger than 11/4?IPS, including both pipe and tubing sizes. 1.7?Tests will be performed at 67?°F ± 10?°F (19.4?°C ± 5.5?°C). Alternative optional test temperatures are 100?°F?± 10?°F (37.7?°C ± 5.5?°C) and 0 ± 10°F (?18 ± 5.5°C). All flow rates must be corrected to standard conditions. 1.8?This test method was written for EFVs installed in thermoplastic piping systems. However, it is expected that the test method may also be used for similar devices in other piping systems. 1.9?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.10?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautions, see Section 8. 1.11?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
국제분류(ICS)코드 | 23.060.20 : 보올 밸브 |
페이지수 | 9 |
Edition | 22 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM F1802-22 | Standard Test Method for Performance Testing of Excess Flow Valves | 2022-02-01 | 표준 |
2 | ASTM F1802-22 REDLINE | Standard Test Method for Performance Testing of Excess Flow Valves | 2022-02-01 | 표준 |
3 | ASTM F1802-15 REDLINE | Standard Test Method for Performance Testing of Excess Flow Valves | 2015-11-01 | 구판 |
4 | ASTM F1802-15 | Standard Test Method for Performance Testing of Excess Flow Valves | 2015-11-01 | 구판 |
5 | ASTM F1802-04(2010) | Standard Test Method for Performance Testing of Excess Flow Valves | 2010-08-01 | 구판 |
6 | ASTM F1802-04 | Standard Test Method for Performance Testing of Excess Flow Valves | 2004-04-01 | 구판 |
7 | ASTM F1802-97 | Standard Test Method for Performance Testing of Excess Flow Valves | 1997-05-10 | 구판 |
관련상품이 존재하지 않습니다.
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기