관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | 13.01 : 의료기, 외과용 도구 및 장비 |
---|---|
적용범위 | 1.1?These test methods cover the materials and methods for the static and fatigue testing of spinal implant assemblies in a vertebrectomy model. The test materials for most combinations of spinal implant components can be specific, depending on the intended spinal location and intended method of application to the spine. 1.2?These test methods are intended to provide a basis for the mechanical comparison among past, present, and future spinal implant assemblies. They allow comparison of spinal implant constructs with different intended spinal locations and methods of application to the spine. These test methods are not intended to define levels of performance, since sufficient knowledge is not available to predict the consequences of the use of a particular device. 1.3?These test methods set out guidelines for load types and methods of applying loads. Methods for three static load types and one fatigue test are defined for the comparative evaluation of spinal implant assemblies. 1.4?These test methods establish guidelines for measuring displacements, determining the yield load, and evaluating the stiffness and strength of the spinal implant assembly. 1.5?Some spinal constructs may not be testable in all test configurations. 1.6?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.7?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
국제분류(ICS)코드 | 11.040.40 : 외과. 보철술. 교정술용 이식 |
페이지수 | 21 |
Edition | 21 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM F1717-21 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2021-04-01 | 표준 |
2 | ASTM F1717-21 REDLINE | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2021-04-01 | 표준 |
3 | ASTM F1717-18 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2018-06-01 | 구판 |
4 | ASTM F1717-18 REDLINE | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2018-06-01 | 구판 |
5 | ASTM F1717-15 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2015-05-01 | 구판 |
6 | ASTM F1717-14 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2014-01-01 | 구판 |
7 | ASTM F1717-13 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2013-02-01 | 구판 |
8 | ASTM F1717-12a | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2012-12-01 | 구판 |
9 | ASTM F1717-12 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2012-05-15 | 구판 |
10 | ASTM F1717-11a | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2011-07-01 | 구판 |
11 | ASTM F1717-11 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2011-06-01 | 구판 |
12 | ASTM F1717-10 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2010-07-01 | 구판 |
13 | ASTM F1717-09 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2009-09-15 | 구판 |
14 | ASTM F1717-04 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2004-04-01 | 구판 |
15 | ASTM F1717-96 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2001-12-10 | 구판 |
16 | ASTM F1717-01 | Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model | 2001-12-10 | 구판 |
관련상품이 존재하지 않습니다.
ASTM F2267-22 - Standard Test Method for Measuring Load-Induced Subsidence of Intervertebral Body Fusion Device Under Static Axial Compression 상세보기
ASTM F2077-22 - Standard Test Methods for Intervertebral Body Fusion Devices 상세보기
ASTM F1541-17 - Standard Specification and Test Methods for External Skeletal Fixation Devices 상세보기
ASTM F2345-21 - Standard Test Methods for Determination of Cyclic Fatigue Strength of Ceramic Modular Femoral Heads 상세보기
ASTM F1798-21 - Standard Test Method for Evaluating the Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Implants 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기