분야 | ISO/TC 147/SC 3 : Radioactivity measurements |
---|---|
적용범위 | This document specifies methods used to determine the concentration of plutonium and neptunium isotopes in water by inductively coupled plasma mass spectrometry (ICP-MS) (239Pu, 240Pu, 241Pu and 237Np). The concentrations obtained can be converted into activity concentrations of the different isotopes[9]. Due to its relatively short half-life and 238U isobaric interference, 238Pu can hardly be measured by this method. To quantify this isotope, other techniques can be used (ICP-MS with collision-reaction cell, ICP-MS/MS with collision-reaction cell or chemical separation). Alpha spectrometry measurement, as described in ISO 13167[10], is currently used[11]. This method is applicable to all types of water having a saline load less than 1 g·l−1. A dilution of the sample is possible to obtain a solution having a saline load and activity concentrations compatible with the preparation and the measurement assembly. A filtration at 0,45 μm is needed for determination of dissolved nuclides. Acidification and chemical separation of the sample are always needed. The limit of quantification depends on the chemical separation and the performance of the measurement device. This method covers the measurement of those isotopes in water in activity concentrations between around[12][13]: — 1 mBq·l−1 to 5 Bq·l−1 for 239Pu, 240Pu and 237Np; — 1 Bq·l−1 to 5 Bq·l−1 for 241Pu. In both cases, samples with higher activity concentrations than 5 Bq·l−1 can be measured if a dilution is performed before the chemical separation. It is possible to measure 241Pu following a pre-concentration step of at least 1 000. |
국제분류(ICS)코드 |
13.280 : 방사능 보호
17.240 : 방사능 측정 13.060.60 : 수질의 물리적 특성 검사 |
페이지수 | 13 |
Edition | 1 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ISO 20899:2018 | Water quality — Plutonium and neptunium — Test method using ICP-MS | 2018-08-31 | 표준 |
관련상품이 존재하지 않습니다.
ISO 9698:2019 - Water quality — Tritium — Test method using liquid scintillation counting 상세보기
ISO 10704:2019 - Water quality — Gross alpha and gross beta activity — Test method using thin source deposit 상세보기
ISO 11704:2018 - Water quality — Gross alpha and gross beta activity — Test method using liquid scintillation counting 상세보기
ISO 22125-1:2019 - Water quality — Technetium-99 — Part 1: Test method using liquid scintillation counting 상세보기
ISO 22125-2:2019 - Water quality — Technetium-99 — Part 2: Test method using inductively coupled plasma mass spectrometry (ICP-MS) 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기