관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | TC 48/SC 48B : Electrical connectors |
---|---|
적용범위 | IEC 60512-23-3:2018. defines a standard test method for measuring the shielding effectiveness SE of a shielded connector, or of a connector not provided with integral shield once fitted with a shielding accessory and terminated with a screened cable. The complete assembly has a continuous 360° shielding capability throughout its length. This test method can be applied to shielded connectors and to connector accessories with shielding capability. The following different connector designs can be tested: - circular connectors; - rectangular connectors; - connectors for printed boards; - connector shielding accessories. This test method utilizes the principle that the intrinsic shielding property of the connector/ accessory/cable assembly is its surface transfer impedance ZT which can be expressed as the longitudinal voltage inside the shield, relative to the current flow on the outside shell. This test is also suitable for measuring the shielding effectiveness of a connector fitted with triaxial contacts terminated with shielded, twisted pair cables, as used in data bus systems. This second edition cancels and replaces the first edition, published in 2000. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) an introduction has been added to provide some guidance to this document in view of concurrent test method 23g in the same family; b) the frequency range for which this test method is considered reliable moved from 1 GHz to 3 GHz, to be consistent with Figure 7 (unchanged) and current industry practice and need; c) update to IEC 62153-4-6:2017 of former normative reference IEC 60096-4-1:1990, withdrawn and incorrect (should have been IEC 61196-1:1995, also withdrawn); d) update to current subclause numbers of IEC 62153-4-6:2017 what were the previous subclause numbers referenced in IEC 61196-1:1995 (wrongly attributed to IEC 60096-4-1:1990). For immediate understanding the title of these subclauses has been added; e) alignment of title to the current scope of SC 48B (connectors) and inclusion of electrical equipment as target application of said connectors (per current scope of TC 48) and explicit reference to the method – line injection – for the measurement of transfer impedance; f) symbols SE for shielding effectiveness and ZT for surface transfer impedance added throughout the document; g) list of connectors to which the test method is applicable – previously in 3.1 – moved in scope; h) former name of AECMA organization changed to the current ASD-STAN; i) “specimen” used instead of “sample” throughout the document; j) clarification in the title of what transfer impedance is described in Table 3 and editorial improvement of the same; k) “dielectric constant” changed into the updated term “relative permittivity”; l) added a note to warn about the fact that this test method requires in 6.6 a TDR with more stringent rise time of less than 100 ps than the value of less than 350 ps specified both in IEC 62153-4-6 and in EN 50289-1-6 for the similar line injection method applied to screened cables, whereas test 23g of IEC 60512-23-7 specifies for the same purpose a TDR with a rise time of less than 200 ps; m) adoption of term “connector housing” [IEV 581-27-10] instead of “shell” to address the connector accessory providing the shielding; n) title “Transfer impedance ZT [Ω]” added to the ordinate axis on the left side of double log diagram of Figure 7; o) explanatory note to clarify the conversion formula for SE from ZT added. Key words: Connectors, Screening and Filtering Tests, Shielding Effectiveness |
국제분류(ICS)코드 | 31.220.01 : 일반 전기 기계 부품 |
페이지수 | 30 |
Edition | 2.0 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 60512-23-3:2018 RLV | Connectors for electrical and electronic equipment - Tests and measurements - Part 23-3: Screening and filtering tests - Test 23c: Shielding effectiveness of connectors and accessories - Line injection method | 2018-12-14 | 표준 |
2 | IEC 60512-23-3:2018 | Connectors for electrical and electronic equipment - Tests and measurements - Part 23-3: Screening and filtering tests - Test 23c: Shielding effectiveness of connectors and accessories - Line injection method | 2018-12-14 | 표준 |
3 | IEC 60512-23-3:2000/COR1:2003 | Corrigendum 1 - Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 23-3: Test 23c: Shielding effectiveness of connectors and accessories | 2003-04-17 | 구판 |
4 | IEC 60512-23-3:2000 | Electromechanical components for electronic equipment - Basic testing procedures and measuring methods - Part 23-3: Test 23c: Shielding effectiveness of connectors and accessories | 2000-12-21 | 구판 |
IEC 60512-3:1976 - Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 3: Current-carrying capacity tests 상세보기
IEC 60512-4:1976 - Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 4: Dynamic stress tests 상세보기
IEC 60512-6:1984 - Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 6: Climatic tests and soldering tests 상세보기
IEC 60512-2:1985 - Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 2: General examination, electrical continuity and contact resistance tests, insulation tests and voltage stress tests 상세보기
IEC 60512-5:1992 - Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests 상세보기
SAE USCAR12-6 - ELECTRICAL CONNECTOR DESIGN REQUIREMENTS 상세보기
SAE USCAR21-4 - PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS 상세보기
IEC 62153-4-7:2021 RLV - Metallic cables and other passive components test methods - Part 4-7: Electromagnetic compatibility (EMC) - Test method for measuring of transfer impedance ZT and screening attenuation aS or coupling attenuation aC of connectors and assemblies - Triaxial tube in tube method 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기