관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
언어 | 제공형태 | 판매가격 | 선택 |
---|---|---|---|
영어 |
보안PDF |
285,800원 |
|
분야 | |
---|---|
적용범위 | Preface This volume contains the seventh edition of CSA B64.10, Selection and installation of backflow preventers, and the fourth edition of CSA B64.10.1, Maintenance and field testing of backflow preventers. CSA B64.10 supersedes the previous editions published in 2011, 2007, 2001, 1994, 1988 (as part of the CAN/CSA-B64 Series), and 1981. CSA B64.10.1 supersedes the previous editions published in 2011, 2007 and 2001.? This edition includes the following major changes:? a) updates to zone protection piping identification;? b) addition of emergency eye wash station for zone protection;? c) clarification on field testing installation;? d) addition of cross-connection control surveyor specifications;? e) removal of DCVAF double check valve for fire protection systems; and? f) addition of requirements for enclosures with no minimum thermal resistance (R) value.? The two Standards are intended as a guide for designers of potable water supply and plumbing systems in the selection of the proper type of device, for installers and owners in the installation and maintenance of the devices, and for inspection authorities in the testing of the devices after they have been installed. The Standards provide information on other methods of preventing contamination of potable water by backflow from back siphonage or back pressure.? CSA B64.10 and CSA B64.10.1 provide selection criteria, installation and maintenance procedures, and techniques that represent the general state of the art, but should not be construed as all-inclusive, especially where procedures and techniques are altered to meet special conditions. Where there are problems with a specific installation, it is suggested that the manufacturer of the backflow preventer be consulted.? ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------- B64.10-17 - Selection and installation of backflow preventers? Scope 1.1 Application? This Standard specifies requirements for the selection and installation of backflow preventers. Additional information on how backflow due to back siphonage and back pressure occurs, and how to select and apply specific devices, is included in Annexes A, B, and C.? 1.2 Exclusions? 1.2.1 This Standard does not specify requirements for materials, construction, or performance tests of backflow preventers. Such requirements are specified in the CSA B64 Series, in ASME A112.18.1/CSA B125.1, and in CSA B125.3. See Table 1.? 1.2.2 This Standard does not specify requirements for maintenance or field testing after the initial installation. Such requirements are specified in CSA B64.10.1.? 1.3 Terminology? In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.? Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.? Notes to tables and figures are considered part of the table or figure and may be written as requirements.? Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.? 1.4 Measurement? This Standard is written in SI (metric) units. For conversion tables, see Annex D. Vacuum is expressed in pressure below ambient.? ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------- B64.10.1-17 - Maintenance and field testing of backflow preventers? Scope 1.1 This Standard specifies requirements for the maintenance and field testing of backflow preventers.? 1.2 This Standard does not specify requirements for the selection and installation of backflow preventers. Such requirements are specified in CSA B64.10.? 1.3 In CSA standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.? Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.? Notes to tables and figures are considered part of the table or figure and may be written as requirements.? Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.? 1.4 This Standard is written in SI (metric) units. For conversion tables, see Annex D of CSA B64.10. Vacuum is expressed in pressure below ambient. |
국제분류(ICS)코드 | |
페이지수 | 162 |
Edition |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | CSA B64.10:23/CSA B64.10.1:23 | Selection and installation of backflow preventers/Maintenance and field testing of backflow preventers | 2023-01-01 | 표준 |
관련상품이 존재하지 않습니다.
CSA B214:21 - Installation code for hydronic heating systems 상세보기
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기