분야 | 11.01 : 물 (Ⅰ) | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
적용범위 | 1.1 These test methods cover the determination of trace (μg/L) levels of fluoride, acetate, formate, chloride, phosphate, and sulfate in high purity water using ion chromatography in combination with sample preconcentration. Other anions, such as bromide, nitrite, nitrate, sulfite, and iodide can be determined by this method. However, since they are rarely present in significant concentrations in high purity water, they are not included in this test method. Two test methods are presented and their ranges of application, as determined by a collaborative study, are as follows:
A Limit of detection is lowest measurable concentration not reportable as zero at 99 % level of confidence as per EPRI study as cited in Sections 15 and 23. B Insufficient data to calculate limit of detection. 1.2 It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices. 1.3 The common practical range of Test Method A is as follows: chloride, 1 to 100 μg/L, phosphate, 3 to 100 μg/L, and sulfate, 2 to 100 μg/L. 1.4 The common practical range of Test Method B is as follows: fluoride, 1 to 100 μg/L, acetate, 10 to 200 μg/L, and formate, 5 to 200 μg/L. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 7.1 This test method is optimized for the quantitative determination of trace levels of chloride, phosphate, and sulfate. Anions such as fluoride, acetate, and formate can be detected by this method, but are not reliably resolved from each other. See Fig. 1 for a typical chromatogram. 7.2 Using a concentrated sample volume of 20 mL, the test method is applicable in the range outlined in Section 1. The range of this test method may be extended by concentrating a smaller or a larger sample volume. Be sure not to exceed concentrator column breakthrough volume (see annex). 16.1 This test method is optimized for the quantitative determination of trace levels of fluoride, acetate, and formate in high purity water and in water containing up to 2000 mg/L boron from boric acid. The range of the method is summarized in Section 1. See Fig. 3 for a typical chromatogram. 16.2 This test method does not respond to sulfate, since its elution time is very long. 16.3 Using a concentrated sample volume of 20 mL, the test method is applicable in the range outlined in Section 1. The range of this method may be extended upward by concentrating a smaller sample volume, or downward by concentrating a larger sample volume. When analyzing samples containing high amounts of boric acid (for example, 1 %), the volume concentrated should not exceed 30 mL, so as not to exceed the breakthrough volume for fluoride. |
||||||||||||||||||||||||||||||||||||
국제분류(ICS)코드 | |||||||||||||||||||||||||||||||||||||
페이지수 | 9 | ||||||||||||||||||||||||||||||||||||
Edition | 04(2009) |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM D5542-16 REDLINE | Standard Test Methods for Trace Anions in High Purity Water by Ion Chromatography | 2016-06-01 | 표준 |
2 | ASTM D5542-16 | Standard Test Methods for Trace Anions in High Purity Water by Ion Chromatography | 2016-06-01 | 표준 |
3 | ASTM D5542-04(2009) | Standard Test Methods for Trace Anions in High Purity Water by Ion Chromatography | 2009-05-01 | 구판 |
4 | ASTM D5542-04 | Standard Test Methods for Trace Anions in High Purity Water by Ion Chromatography | 2004-06-01 | 구판 |
5 | ASTM D5542-94(1999)e1 | Standard Test Methods for Trace Anions in High Purity Water by Ion Chromatography | 1999-06-10 | 구판 |
관련상품이 존재하지 않습니다.
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기