관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | 13.01 : 의료기, 외과용 도구 및 장비 |
---|---|
적용범위 | 1.1 These test methods cover the determination of the durability of a vascular stent by exposing it to physiologically relevant diametric distension levels by means of hydrodynamic pulsatile loading. This testing occurs on a stent test specimen that has been deployed into a mock (elastically simulated) vessel. The typical duration of this test is 10 years of equivalent use (at 72 beats per minute), or at least 380 million cycles. 1.2 These test methods are applicable to balloon-expandable and self-expanding stents fabricated from metals and metal alloys. It does not specifically address any attributes unique to coated stents, polymeric stents, or biodegradable stents, although the application of this test method to those products is not precluded. 1.3 These test methods do not include recommendations for endovascular grafts ("stent-grafts") or other conduit products commonly used to treat aneurismal disease or peripheral vessel trauma or to provide vascular access, although some information included herein may be applicable to those devices. 1.4 These test methods are valid for determining stent failure due to typical cyclic blood vessel diametric distension. These test methods do not address other modes of failure such as dynamic bending, torsion, extension, crushing, or abrasion. 1.5 These test methods do not address test conditions for curved mock vessels. 1.6 These test methods do not address test conditions for overlapping stents. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.8 General Caveat—This document contains guidance for testing as is currently carried out in most laboratories. Other testing techniques may prove to be more effective and are encouraged. Whichever technique is used, it is incumbent upon the tester to justify the use of the particular technique, instrument, and protocol. This includes the choice of and proper calibration of all measuring devices. Deviations from any of the suggestions in this document may be appropriate but may require the same level of comprehensive justification that the techniques described herein will require. |
국제분류(ICS)코드 | |
페이지수 | 10 |
Edition | 07 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | ASTM F2477-24 | Standard Test Methods for |
2024-07-15 | 표준 |
2 | ASTM F2477-24 REDLINE | Standard Test Methods for |
2024-07-15 | 표준 |
3 | ASTM F2477-23 | Standard Test Methods for |
2023-02-01 | 구판 |
4 | ASTM F2477-23 REDLINE | Standard Test Methods for |
2023-02-01 | 구판 |
5 | ASTM F2477-19 | Standard Test Methods for |
2019-06-01 | 구판 |
6 | ASTM F2477-19 REDLINE | Standard Test Methods for |
2019-06-01 | 구판 |
7 | ASTM F2477-07(2013) | Standard Test Methods for |
2013-03-01 | 구판 |
8 | ASTM F2477-07 | Standard Test Methods for in vitro Pulsatile Durability Testing of Vascular Stents | 2007-04-01 | 구판 |
9 | ASTM F2477-06 | Standard Test Methods for |
2006-11-01 | 구판 |
관련상품이 존재하지 않습니다.
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기